Product information
Overview
Key Features
- Rated power and overload: Rated output power: 45.00 kW (50.00 hp) LO and 37.00 kW (40.00 hp) HO; the collected data specifies 150% overload for 3 s.
- Input and output ratings: Input: 380 … 480 V 3AC, +10 % -20 %, 47 … 63 Hz. Output frequency: 0 … 240 Hz for vector control and 0 … 550 Hz for V/f control.
- Control and safety: Has V/f linear, square-law and parameterizable control, V/f with flux current control, V/f ECO linear and square-law control, sensorless vector control, and integrated Safe Torque Off.
- I/O and communication: I/O: 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog/digital input with 10 bit resolution, and 1 non-isolated analog output. Communication: PROFINET and EtherNet/IP.
- Connections and protection: Has screw-type terminals for the line side, motor end, DC link and PE connection. Degree of protection: IP20 / UL open type; frame size: FSD.
Technical Summary
| Product | 6SL3210-1KE28-4AF1 |
|---|---|
| Product family | SINAMICS G120C |
| Rated output power, LO | 45.00 kW | 50.00 hp |
| Rated output power, HO | 37.00 kW | 40.00 hp |
| Input | 380 … 480 V 3AC +10 % -20 %; 47 … 63 Hz |
| Output frequency, vector control | 0 … 240 Hz |
| Output frequency, V/f control | 0 … 550 Hz |
| Communication | PROFINET, EtherNet/IP |
| I/O | 6 DI, 1 fail-safe DI, 2 DO, 1 AI, 1 AO |
| Safety | Safe Torque Off integrated |
| Degree of protection | IP20 / UL open type |
Frequently Asked Questions
What is the rated power of Siemens 6SL3210-1KE28-4AF1?
Rated output power is 45.00 kW (50.00 hp) under LO conditions and 37.00 kW (40.00 hp) under HO conditions.
Which control methods does this SINAMICS G120C support?
It supports V/f linear, square-law and parameterizable control, V/f with flux current control, V/f ECO linear and square-law control, and sensorless vector control.
What communication interfaces and I/O does it have?
Communication is PROFINET and EtherNet/IP. The I/O includes 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog/digital input and 1 non-isolated analog output.
What protection and connections are provided?
Degree of protection is IP20 / UL open type. The line side, motor end, DC link and PE connection use screw-type terminals.
What information should I provide for a quotation?
Provide the required quantity, destination and requested date so the exact model can be reviewed for an MRO or project quotation.