Product information
Overview
Key Features
- Rated power: 4.00 kW at low overload and 3.00 kW at high overload.
- Input supply: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz.
- Output frequency: 0 … 240 Hz for vector control and 0 … 550 Hz for V/f control.
- I/O and communication: 6 standard digital inputs, 1 fail-safe digital input, 1 analog input, 1 analog output, digital outputs with 1 relay changeover contact and 1 transistor, plus PROFINET and EtherNet/IP.
- Control techniques: V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
- Protection and size: IP20 / UL open type, frame size FSA, 73 mm width and 200 mm depth.
Technical Summary
| Product | 6SL3210-1KE18-8UF1 |
|---|---|
| Product family | SINAMICS G120C |
| Rated power, low overload | 4.00 kW | 5.00 hp |
| Rated power, high overload | 3.00 kW | 4.00 hp |
| Input | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Communication | PROFINET, EtherNet/IP |
| Standard digital inputs | 6 |
| Fail-safe digital inputs | 1 |
| Analog input | 1 (Differential input) |
| Protection | IP20 / UL open type |
| Frame size | FSA |
Frequently Asked Questions
What are the low- and high-overload ratings of 6SL3210-1KE18-8UF1?
The low-overload rating is 4.00 kW | 5.00 hp, and the high-overload rating is 3.00 kW | 4.00 hp.
Which communication interfaces does this SINAMICS G120C have?
It has PROFINET and EtherNet/IP communication.
What I/O is available?
It has 6 standard digital inputs, 1 fail-safe digital input, 1 differential analog input, 1 non-isolated analog output, 1 relay changeover contact, and 1 transistor output.
What are the protection rating and frame size?
Protection is IP20 / UL open type, and the frame size is FSA.
What information should I provide for a quotation?
Please provide the required quantity, destination, and requested date for quotation review.