Overview
Key Features
- Rated power and overload: Rated output power is 3.00 kW | 4.00 hp for low overload and 2.20 kW | 3.00 hp for high overload. Low overload: 150% for 3s, 110% for 57s, 100% for 240s; high overload: 200% for 3s, 150% for 57s, 100% for 240s.
- Input and output ratings: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Output: 3 AC, rated voltage 400V IEC | 480V NEC, with maximum output current 11.20 A.
- I/O and safety: The interface has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input and 1 non-isolated analog output. Safe Torque Off is integrated.
- Control and communication: Supported control includes V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law and sensorless vector control. Communication: USS/MODBUS RTU.
- Connections and protection: Line-side, motor-end and DC-link connections use plug-in screw terminals. Protection: IP20 / UL open type. Frame size: FSA; width 73 mm (2.87 in), depth 203 mm (7.99 in).
Technical Summary
| Product type | SINAMICS G120C compact converter |
|---|---|
| Rated input | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Rated output power, low overload | 3.00 kW | 4.00 hp |
| Rated output power, high overload | 2.20 kW | 3.00 hp |
| Maximum output current | 11.20 A |
| Control methods | V/f linear / square-law / parameterizable; V/f with flux current control (FCC); V/f ECO linear / square-law; sensorless vector control |
| I/O | 6DI, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, 1 non-isolated analog output |
| Communication | USS/MODBUS RTU |
| Safety function | Safe Torque Off integrated |
| Protection | IP20 / UL open type |
| Frame size | FSA |
Frequently Asked Questions
What is the exact Siemens model and product type?
The exact model is Siemens 6SL3210-1KE17-5AB1, a SINAMICS G120C compact converter.
What are the low-overload and high-overload output ratings?
Low overload is 3.00 kW | 4.00 hp with 150% for 3s, 110% for 57s and 100% for 240s. High overload is 2.20 kW | 3.00 hp with 200% for 3s, 150% for 57s and 100% for 240s.
Which interfaces and communication protocol are included?
It has 6DI, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, 1 non-isolated analog output and USS/MODBUS RTU communication.
What configuration details should be included in a quotation request?
Please provide the required quantity, destination, requested date and project or replacement-part list for verification.