Product information
Overview
Key Features
- Output power and overload: Rated output power is 2.20 kW | 3.00 hp for low overload and 1.50 kW | 2.00 hp for high overload. Low overload is 150% for 3s, 110% for 57s, and 100% for 240s; high overload is 200% for 3s, 150% for 57s, and 100% for 240s.
- Supply and frequency: Input is 3 AC, 380 … 480 V +10 % -20 %, at 47 … 63 Hz.
- I/O and safety: The converter has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, 1 non-isolated analog output, and integrated Safe Torque Off.
- Control and communication: Supported control includes V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control. Communication is PROFIBUS DP.
- Connections and installation: Line-side, motor-end, and DC-link connections use plug-in screw terminals. Frame size is FSAA; dimensions are 73 mm width and 155 mm depth.
- Protection and cooling: Protection is IP20 / UL open type. Cooling uses an integrated fan.
Technical Summary
| Order number | 6SL3210-1KE15-8AP2 |
|---|---|
| Product lifecycle | Active Product |
| Rated output power (LO) | 2.20 kW | 3.00 hp |
| Rated output power (HO) | 1.50 kW | 2.00 hp |
| Input | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Communication | PROFIBUS DP |
| I/O | 6 digital inputs, 2 digital outputs, 1 analog input, 1 analog output, 1 fail-safe digital input |
| Control | V/f linear / square-law / parameterizable; V/f with flux current control (FCC); V/f ECO linear / square-law; sensorless vector control |
| Frame size | FSAA |
| Protection | IP20 / UL open type |
| Cooling | Air cooling using an integrated fan |
Frequently Asked Questions
What is the exact model and lifecycle status?
The exact model is Siemens 6SL3210-1KE15-8AP2, and its lifecycle is Active Product.
What are the low-overload and high-overload output ratings?
Low-overload output is 2.20 kW | 3.00 hp; high-overload output is 1.50 kW | 2.00 hp. The overload durations and percentages are 150% for 3s, 110% for 57s, and 100% for 240s at low overload, and 200% for 3s, 150% for 57s, and 100% for 240s at high overload.
Which communication interface and I/O are provided?
Communication is PROFIBUS DP. I/O includes 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, and 1 non-isolated analog output.
What protection and mounting configuration does it have?
It has IP20 / UL open type protection and FSAA frame size. Line-side, motor-end, and DC-link connections use plug-in screw terminals.