Product information
Overview
Key Features
- Rated input: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Rated current is 4.10 A for low overload and 3.20 A for high overload.
- Overload output ratings: Low overload: 1.10 kW | 1.50 hp at 150% for 3s, 110% for 57s, and 100% for 240s. High overload: 0.75 kW | 1.00 hp at 200% for 3s, 150% for 57s, and 100% for 240s.
- Control and output frequency: Output frequency is 0 … 240 Hz for vector control and 0 … 550 Hz for V/f control. Supported techniques include V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
- I/O and safety: The external 24V I/O interface has 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog/digital input with 10 bit resolution, and 1 non-isolated analog output. Safe Torque Off is integrated.
- Communication: Fieldbus: PROFIBUS DP.
- Connections and protection: Line-side, motor-end, and DC-link connections use plug-in screw terminals. Protection: IP20 / UL open type. Frame size: FSAA.
Technical Summary
| Product type | SINAMICS G120C compact converter |
|---|---|
| Order number | 6SL3210-1KE13-2UP2 |
| Input supply | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Output power, low overload | 1.10 kW | 1.50 hp |
| Output power, high overload | 0.75 kW | 1.00 hp |
| Output frequency | 0 … 240 Hz vector control; 0 … 550 Hz V/f control |
| I/O interface | 6DI, 2DO, 1AI, 1AO, 1 fail-safe digital input |
| Communication | PROFIBUS DP |
| Control techniques | V/f linear / square-law / parameterizable; V/f with flux current control (FCC); V/f ECO linear / square-law; sensorless vector control |
| Protection | IP20 / UL open type |
Frequently Asked Questions
What is Siemens 6SL3210-1KE13-2UP2?
It is a SINAMICS G120C compact converter with 3 AC 380 … 480 V +10 % -20 % input, PROFIBUS DP communication, and integrated Safe Torque Off.
What are its low-overload and high-overload output ratings?
Low overload is 1.10 kW | 1.50 hp at 150% for 3s, 110% for 57s, and 100% for 240s. High overload is 0.75 kW | 1.00 hp at 200% for 3s, 150% for 57s, and 100% for 240s.
What I/O and connection interfaces does it have?
It has 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog/digital input, 1 non-isolated analog output, and plug-in screw terminals for line-side, motor-end, and DC-link connections.
What protection and mechanical variant does it use?
Protection is IP20 / UL open type. The frame size is FSAA, with 73 mm width and 155 mm depth.
What information should I include for a quotation request?
Include the required quantity, destination, requested date, and any project list or technical verification requirements for 6SL3210-1KE13-2UP2.