Product information
Overview
Applications
- Switching voltage buses: The 24 V DC module switches the P1 and P2 voltage buses up to Category 3 according to EN 954-1, SIL 2 according to IEC 61508 and PL d according to ISO 13849.
- Fail-safe digital output control: It provides 2 fail-safe digital outputs up to Category 4 according to EN 954-1, SIL 3 according to IEC 61508 and PL e according to ISO 13849.
- PROFINET configuration: It can be used in a PROFINET configuration with IM 151-3 HF.
Key Features
- 24 V DC load voltage: Rated load voltage L+: 24 V DC; reverse polarity protection: No.
- Fail-safe digital outputs: The module has 2 digital outputs with electronic short-circuit protection and a rated signal-1 output current of 2 A.
- Safety capability: Highest safety class achievable in safety mode: Category 4 according to EN 954, Performance Level e according to ISO 13849-1, and up to SIL 3 according to IEC 61508.
- Output diagnostics: Diagnostics include wire break, short-circuit and missing load voltage detection, with PWR, SF and digital-output status LEDs.
- ET200S configuration: The module is suitable for an ungrounded setup and can also be used in a PROFINET configuration with IM 151-3 HF.
- Mechanical dimensions: Dimensions: 30 mm width, 81 mm height and 52 mm depth; approximate weight: 88 g.
Technical Summary
| Product | SIMATIC DP Power Module PM-E F PROFIsafe for ET200S |
|---|---|
| Load voltage L+ | 24 V DC |
| Digital outputs | 2 |
| Rated signal-1 output current | 2 A |
| Permissible signal-1 output current for 0 to 60 °C | 20 mA to 2.4 A |
| Switching frequency with resistive load, max. | 30 Hz |
| Safety capability | Category 4 according to EN 954; Performance Level e according to ISO 13849-1; up to SIL 3 according to IEC 61508 |
| Product lifecycle | Product cancellation |
Frequently Asked Questions
What is the exact product type of 6ES7138-4CF03-0AB0?
It is a SIMATIC DP Power Module PM-E F PROFIsafe for ET200S.
What load voltage does 6ES7138-4CF03-0AB0 use?
Its rated load voltage L+ is 24 V DC.
How many fail-safe digital outputs does the module have?
It has 2 digital outputs with electronic short-circuit protection.
What safety levels are supported?
The highest achievable safety capability is Category 4 according to EN 954, Performance Level e according to ISO 13849-1 and up to SIL 3 according to IEC 61508.
What configuration details should be included for a quotation?
Include the required quantity and destination for an MRO or project quotation.