Product information
Overview
Applications
- Connecting ET-CONNECTION nodes: Used for connecting ET-CONNECTION nodes, e.g. SIMATIC ET 200AL, in degree of protection IP65/67.
Key Features
- Bus cable configuration: Flexible 4-core shielded cable, preassembled at one end with 1x M8 plug, 4-pin.
- ET connection suitability: For connecting ET-CONNECTION nodes, e.g. SIMATIC ET 200AL, in degree of protection IP65/67.
- Cable length and designation: Cable length: 2 m. Cable designation: 2Y(ST)CY 1x4x0.5/1.0-100-GN.
- Bending performance: 1 000 000 bending cycles; cable carrier compliant for 1 million bending cycles with a bending radius of 100 mm, a speed of 4 m/s and an acceleration of 4 m/s2.
- Temperature during assembly: Ambient temperature during assembly: -30 °C to 80 °C.
- Cable construction: 180° cable outlet, PVC cable sheath, PE core insulation, silicone-free; halogen-free: No.
Technical Summary
| Product type | Bus cable |
|---|---|
| Connection | 1x preassembled 4-pin M8 plug at one end |
| Number of electrical cores | 4 |
| IP degree of protection | IP65/67 |
| Cable designation | 2Y(ST)CY 1x4x0.5/1.0-100-GN |
| Bending radius, continuous bending | 100 mm |
| Bending radius, single bend, min. | 20 mm |
| Bending radius, multiple bends, min. | 40 mm |
| Ambient temperature during assembly | -30 °C to 80 °C |
| Cable sheath color | green |
Frequently Asked Questions
What is the exact product type of Siemens 6ES7194-2LH20-0AC0?
It is a bus cable for ET connection M8.
How is the cable configured?
It is a flexible 4-core shielded cable with 1x preassembled 4-pin M8 plug at one end.
What are the cable length and protection rating?
The cable length is 2 m and the protection rating is IP65/67.
What bending-radius limits are specified?
The minimum permissible bending radius is 20 mm for a single bend and 40 mm for multiple bends; continuous bending uses 100 mm.
What information should be included for a quotation?
Please provide the required quantity and destination for an MRO or project quotation.