ET 200AL Distributed I/O Parts

6ES7141-5BF00-0BL0

Product details

Product Code
6ES7141-5BF00-0BL0
Dimensions
17.9 × 4.7 × 4.2 cm
Weight
0.143 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet

Pricing, condition, availability and delivery terms are confirmed against the exact product reference.

Product information

Overview

Key Features

  • 8 digital inputs: Digital input capacity: 8; sourcing/sinking input: P-reading; input characteristic curve according to IEC 61131, type 3.
  • IO-Link 1.1 interface: Supports IO-Link protocol 1.1 with 38.4 kBd (COM2), 2.1 ms minimum cycle time and Port type A connections.
  • 24 V DC input voltage: Rated input voltage: 24 V DC; signal "0": -30 to +5 V; signal "1": +11 to +30V.
  • M8 and M12 connections: Inputs and outputs use M8, 3-pole connections; IO-Link uses M12, 5-pin, A-coded connections.
  • IP65/67 protection: IP degree of protection: IP65/67. Ambient temperature during operation: -30 °C to 55 °C.
  • Configurable diagnostics: Diagnostic alarm is parameterizable; short-circuit diagnostics are provided sensor supply to M, module by module, with green channel-status LEDs.

Technical Summary

Product type designation IO-Link DI 8x24VDC
Digital inputs 8
Input voltage, rated value 24 V DC
IO-Link protocol 1.1
IO-Link transmission rate 38.4 kBd (COM2)
IO-Link cycle time, min. 2.1 ms
Process data, input per module 1 byte
Connection for inputs and outputs M8, 3-pole
Connection for IO-Link M12, 5-pin, A-coded
IP degree of protection IP65/67
Ambient temperature during operation -30 °C to 55 °C
Firmware version V1.0.x

Frequently Asked Questions

What is the exact product type of Siemens 6ES7141-5BF00-0BL0?

The product type designation is IO-Link DI 8x24VDC, with HW functional status FS01 and firmware version V1.0.x.

How many digital inputs does the module have?

It has 8 digital inputs with a P-reading sourcing/sinking input and an IEC 61131, type 3 input characteristic curve.

Which connections are provided?

The inputs and outputs use M8, 3-pole connections, while the IO-Link connection uses M12, 5-pin, A-coded.

What IO-Link specifications should be verified?

The module supports IO-Link protocol 1.1, 38.4 kBd (COM2), a 2.1 ms minimum cycle time and 1 byte of input process data per module.

How can I request a quotation for this configuration?

Send the required quantity, destination and project-list context for a model-specific quotation request.