Product information
Overview
Key Features
- Analog output capacity: Has 2 analog outputs with voltage and current output ranges.
- Output ranges: Voltage ranges: 0 to 10 V, 1 V to 5 V, and -10 V to +10 V. Current ranges: 0 to 20 mA, -20 mA to +20 mA, and 4 mA to 20 mA.
- Resolution and conversion: Resolution with overrange, max.: 12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, and 1 V to 5 V: 11 bit + sign; 0 V to 10 V and 0 mA to 20 mA: 12 bit. Conversion time per channel: 0.8 ms.
- Supply and protection: Load voltage L+ rated value (DC): 24 V. Reverse polarity protection and voltage-output short-circuit protection: Yes.
- Connections and installation: Required front connector: 20-pin. Supports voltage-output two-wire and four-wire connections, and current-output two-wire connections. Removing and inserting with the active backplane bus is possible.
- Isolation and diagnostics: Isolation tested with 500 V DC. The analog outputs are isolated from the backplane bus and load voltage L+. Diagnostics, parameterizable diagnostic alarms, readable diagnostic information, and red group error SF indication are supported.
Technical Summary
| Product type | SIMATIC S7-300 isolated analog output SM 332 |
|---|---|
| Analog outputs | 2 |
| Load voltage L+ rated value (DC) | 24 V |
| Voltage output ranges | 0 to 10 V; 1 V to 5 V; -10 V to +10 V |
| Current output ranges | 0 to 20 mA; -20 mA to +20 mA; 4 mA to 20 mA |
| Resolution with overrange, max. | 12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit |
| Conversion time per channel | 0.8 ms |
| Required front connector | 20-pin |
| Product lifecycle | Product cancellation |
Frequently Asked Questions
What is the exact product and configuration?
It is Siemens 6ES7332-5HB01-0AB0, a SIMATIC S7-300 isolated analog output SM 332 module with 2 AO.
Which output signals and ranges does it support?
It supports voltage ranges of 0 to 10 V, 1 V to 5 V, and -10 V to +10 V, plus current ranges of 0 to 20 mA, -20 mA to +20 mA, and 4 mA to 20 mA.
Which connector and actuator connections are required?
It requires a 20-pin front connector and supports voltage-output two-wire and four-wire connections and current-output two-wire connections.
Can removal and insertion be performed with the active backplane bus?
Yes, removing and inserting with the active backplane bus is possible.
How can I request a quotation for this module?
Send the required quantity, destination, and project or MRO list context for a model-specific quotation.