Product information
Overview
Applications
- Safety button monitoring: Supports monitoring of the STOP button, emergency stop button, and acknowledgement button.
- Emergency stop circuit reconnection: Supports reconnection without emergency stop circuit interruption; reconnection with emergency stop circuit interruption is not supported.
Key Features
- Mobile Panel connection: Connection box for Mobile Panels with wall mounting/direct mounting.
- PROFINET interfaces: Has 3 industrial Ethernet interfaces and 3 PROFINET interfaces, with connection point identification.
- Network protocols: Supports PROFINET, PROFIsafe, IRT, EtherNet/IP, TCP/IP, DHCP, SNMP, DCP, LLDP, MRP, and MODBUS.
- Safety monitoring: Supports monitoring of the STOP button, emergency stop button, and acknowledgement button through direct wiring and PROFIsafe.
- Supply and power: Rated supply: 24 V DC; permissible range: 19.2 V to 28.8 V. Current consumption rated value: 95 mA; active power input, typ.: 2.3 W.
- Protection: IP degree of protection: IP65; IP65 all-round and IP65 at the front.
Technical Summary
| Product type | Connection box |
|---|---|
| Mounting | Wall mounting/direct mounting |
| Supply voltage | 24 V DC; permissible range 19.2 V to 28.8 V |
| Industrial Ethernet interfaces | 3 |
| PROFINET interfaces | 3 |
| Protocols | PROFINET, PROFIsafe, IRT, EtherNet/IP, TCP/IP, DHCP, SNMP, DCP, LLDP, MRP, MODBUS |
| Safety monitoring | STOP button, emergency stop button, acknowledgement button |
| Protection | IP65; IP65 all-round and at the front |
| Active power input, typ. | 2.3 W |
Frequently Asked Questions
What is the supply voltage for 6AV2125-2AE23-0AX0?
The rated supply is 24 V DC, with a permissible range from 19.2 V to 28.8 V.
How many PROFINET interfaces does the connection box have?
It has 3 PROFINET interfaces and 3 industrial Ethernet interfaces.
Can this connection box be mounted in a control cabinet?
No. It supports wall mounting/direct mounting; control cabinet installation is not supported.