Product information
Overview
Key Features
- Output power: Rated output power is 45.00 kW | 60.00 hp for low overload and 37.00 kW | 50.00 hp for high overload.
- Overload performance: Low overload: 150% for 3 s, 110% for 57 s, and 100% for 240 s at -20 … 40 °C. High overload: 200% for 3 s, 150% for 57 s, and 100% for 240 s at -20 … 50 °C.
- Input and output: The module has 3 AC input and output phases. Line voltage is 380 … 480 V ±10 %, with a 47 … 63 Hz line frequency.
- Control and braking: Output frequency is 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control. The module includes a braking chopper.
- Connections and protection: It uses screw-type terminals, IP20 / UL open type protection, and frame size FSE. The configuration is without a control unit and panel.
Technical Summary
| Product type | SINAMICS G120 PM240-2 power module |
|---|---|
| Output power (LO) | 45.00 kW | 60.00 hp |
| Output power (HO) | 37.00 kW | 50.00 hp |
| Input voltage | 380 … 480 V ±10 % |
| Line frequency | 47 … 63 Hz |
| Output frequency, vector control | 0 … 200 Hz |
| Output frequency, V/f control | 0 … 550 Hz |
| Protection | IP20 / UL open type |
| Frame size | FSE |
| Configuration | Without control unit and panel |
Frequently Asked Questions
What output ratings does the 6SL3210-1PE28-8AL0 provide?
It provides 45.00 kW | 60.00 hp for low overload and 37.00 kW | 50.00 hp for high overload.
What input supply is specified for this power module?
The input is 3 AC, 380 … 480 V ±10 %, at 47 … 63 Hz.
What control frequency ranges are available?
The output frequency is 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control.
Does the configuration include a control unit or panel?
It is without a control unit and panel.
What information should I provide for a quotation?
Provide the required quantity, destination, and requested date for quotation review.