Product information
Overview
Key Features
- High-overload power rating: Rated output power is 0.75 kW | 1.00 hp (HO), with 200% for 3 s, 150% for 57 s, and 100% for 240 s at -10 … 50 °C ambient temperature.
- Low-overload power rating: Rated output power is 1.10 kW | 1.50 hp (LO), with 150% for 3 s, 110% for 57 s, and 100% for 240 s at -10 … 40 °C ambient temperature.
- Input and output supply: Input: 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz. Output: 3 AC, 400V IEC | 480V NEC.
- Output frequency: Output frequency is 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control.
- Integrated braking chopper: The PM240-2 Power Module has an integrated braking chopper and a 4 kHz pulse frequency.
- Connections and protection: Line-side and motor-end connections use plug-in screw terminals for 1.00 … 2.50 mm2 (AWG 18 … AWG 14) conductors. Degree of protection: IP20 / UL open type.
Technical Summary
| Product | SINAMICS Power Module PM240-2 |
|---|---|
| Input | 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz |
| Rated power (LO) | 1.10 kW | 1.50 hp |
| Rated power (HO) | 0.75 kW | 1.00 hp |
| Rated current (LO) | 3.10 A output |
| Rated current (HO) | 2.20 A output |
| Output frequency | 0 … 200 Hz vector control; 0 … 550 Hz V/f control |
| Frame size | FSA |
| Degree of protection | IP20 / UL open type |
| Connections | Plug-in screw terminals |
| Product lifecycle | Active Product |
Frequently Asked Questions
What is the exact product type of 6SL3210-1PE13-2UL1?
It is a SINAMICS Power Module PM240-2 unfiltered with an integrated braking chopper.
What are the low-overload and high-overload power ratings?
Low overload is 1.10 kW | 1.50 hp; high overload is 0.75 kW | 1.00 hp.
What connections and conductor sizes does it have?
It has plug-in screw terminals on the line side and motor end for 1.00 … 2.50 mm2 (AWG 18 … AWG 14) conductors.
What configuration details should be included in a quotation request?
Include the required quantity, destination, requested date, and project or model list for verification.