Product information
Overview
Key Features
- AC drive with integrated filter: SINAMICS G110-CPM110 AC drive with integrated filter B.
- Supply: 200-240 V 1 AC+10/-10%, 47-63 Hz.
- CT and VT ratings: CT: 0.55 kW; VT: 0.55 kW.
- CT overload: 150% for 60 s.
- Installation and exclusions: IP20; only for cooling plate installation. Without BOP and without RS-485 interface.
- Product status and logistics: Product cancellation; packaging dimensions: 180.00 x 100.00 x 160.00 mm; net weight: 0.800 kg.
Technical Summary
| Product type | SINAMICS G110-CPM110 AC drive |
|---|---|
| Supply | 200-240 V 1 AC+10/-10%, 47-63 Hz |
| Integrated filter | Filter B |
| CT rating | 0.55 kW |
| VT rating | 0.55 kW |
| CT overload | 150% for 60 s |
| Installation | Cooling plate installation only |
| Protection | IP20 |
| Included equipment | Without BOP; without RS-485 interface |
Frequently Asked Questions
Is 6SL3211-0KB15-5BA1 a SINAMICS G110-CPM110 AC drive?
Yes. It is a SINAMICS G110-CPM110 AC drive with integrated filter B.
What supply does this drive use?
The supply is 200-240 V 1 AC+10/-10% at 47-63 Hz.
What are the CT and VT ratings?
The CT rating is 0.55 kW and the VT rating is 0.55 kW. CT overload is 150% for 60 s.
What mounting and protection details apply?
It has IP20 protection and is only for cooling plate installation.
What should I provide for a quotation?
Send the required quantity and destination for an MRO or project quotation.