Overview
Key Features
- Rated motor data: Ratings include 9 kW, 57 Nm, 23.5 A at 330 V and 1500 r/min; 10 kW, 55 Nm, 22 A at 380 V and 1750 r/min; 11 kW, 53 Nm, 21.5 A at 428 V and 2000 r/min; and 12.1 kW, 53 Nm, 21.5 A at 470 V and 2200 r/min.
- Feedback and temperature sensing: HTL 1024 S/R Encoder with KTY84-130 temperature sensor.
- Cooling and air direction: Forced ventilation; air flows from DE to NDE.
- Mounting and shaft: IM B3 design, with IM V5 and IM V6 mounting options; shaft has a fitted key with full-key balancing.
- Mechanical accuracy and bearing: Standard bearing with fixed bearing, vibration severity grade R/A, and shaft and flange accuracy R.
- Protection and connections: IP55 degree of protection. The terminal box is above, with cable entry on the right and signal connection at the D-end.
Technical Summary
| Product type | Compact asynchronous motor |
|---|---|
| Rated power | 9 kW at 1500 r/min; 10 kW at 1750 r/min; 11 kW at 2000 r/min; 12.1 kW at 2200 r/min |
| Rated torque | 57 Nm at 1500 r/min; 55 Nm at 1750 r/min; 53 Nm at 2000 r/min and 2200 r/min |
| Rated voltage | 330 V; 380 V; 428 V; 470 V |
| Rated current | 23.5 A; 22 A; 21.5 A; 21.5 A |
| Feedback | HTL 1024 S/R Encoder |
| Temperature sensor | KTY84-130 |
| Cooling | Forced ventilation; air flow DE–> NDE |
| Mounting | IM B3 (IM V5, IM V6) |
| Protection | IP55 |
Frequently Asked Questions
What motor ratings are available for Siemens 1PH8107-1HF00-1BA1?
The motor has 9 kW at 1500 r/min, 10 kW at 1750 r/min, 11 kW at 2000 r/min, and 12.1 kW at 2200 r/min, with the associated voltage, current and torque values listed in the technical details.
What feedback and temperature sensor does this motor have?
It has an HTL 1024 S/R Encoder and a KTY84-130 temperature sensor.
How is the Siemens 1PH8107-1HF00-1BA1 mounted and connected?
It has an IM B3 design with IM V5 and IM V6 mounting options. The terminal box is above, cable entry is on the right, and the signal connection is at the D-end.
What protection and cooling are specified?
The motor has IP55 protection and forced ventilation, with air flow from DE to NDE.
How can I request a quotation for this motor?
Send the required quantity, destination and requested date for an MRO or project quotation.