Product information
Overview
Key Features
- Motor ratings: PN=2 kW, UDC=600 V, rated speed 3,000 rpm, and rated torque 6.5 Nm (100 K).
- Dynamic performance: Maximum torque: 105.0 Nm; maximum permissible speed: 6,000 rpm mechanically and with inverter.
- Feedback interface: Incremental Encoder 22 bits with 4,194,304 resolution, encoder-internal 2048 S/R, commutation position 11 bits, and DRIVE-CLiQ interface.
- Mechanical configuration: IM B5 mounting (IM V1, IM V3), rotatable M40 connector, shaft with fitted Feather key, tolerance N, and without holding brake.
- Cooling and protection: Natural cooling; degree of protection IP65 and DE flange IP67.
- Temperature monitoring: Pt1000 temperature sensor; electrical connectors for signals and power are rotatable.
Technical Summary
| Product | Siemens SIMOTICS S 1FK7086-4CF71-1DA2 |
|---|---|
| Motor type | Permanent-magnet synchronous motor; High Dynamic |
| Rated power | PN=2 kW |
| Supply voltage | UDC=600 V |
| Rated speed | 3,000 rpm (100 K) |
| Rated torque | 6.5 Nm (100 K) |
| Encoder | Incremental Encoder 22 bits; DRIVE-CLiQ interface |
| Mounting | IM B5 (IM V1, IM V3) |
| Cooling | Natural cooling |
| Protection | IP65 and DE flange IP67 |
| Holding brake | without holding brake |
Frequently Asked Questions
What is the rated performance of Siemens 1FK7086-4CF71-1DA2?
The motor has PN=2 kW, UDC=600 V, rated speed 3,000 rpm (100 K), and rated torque 6.5 Nm (100 K).
Which feedback system and interface does this motor have?
It has an incremental Encoder 22 bits with 4,194,304 resolution, encoder-internal 2048 S/R, commutation position 11 bits, and a DRIVE-CLiQ interface.
What mechanical configuration should be verified?
The motor uses IM B5 mounting (IM V1, IM V3), a rotatable M40 connector, a shaft with fitted Feather key and tolerance N, and is without holding brake.
What protection and cooling are provided?
It has natural cooling and degree of protection IP65, with DE flange IP67.
What information should be included for a quotation?
Please provide the required quantity, destination, requested date, and project or replacement context for model-specific verification.