Product information
Overview
Key Features
- Motor ratings: PN=2kW, UDC=600V, rated speed 3,000 rpm, and rated torque 6.5 Nm (100 K).
- Torque and current limits: Static torque is 23.00 Nm (60 K) and 28.00 Nm (100 K); maximum torque is 105.0 Nm and maximum current is 115.0 A.
- Encoder feedback: Encoder AM24DQI has an absolute encoder with 24 bits (resolution 16777216, encoder-internal 2048 S/R) plus 12 bits multi-turn with a traversing range of 4096 revolutions, using a DRIVE-CLiQ interface.
- Mounting and shaft: Design acc. to Code I: IM B5 (IM V1, IM V3). The motor has a plain shaft, tolerance N, and a rotatable flange 1 power connector.
- Cooling and protection: Cooling is natural. Degree of protection is IP65 and DE flange IP67.
- Brake and connectors: The motor is without holding brake. Electrical connectors for signals and power are rotatable; connector size is M40.
Technical Summary
| Product | 1FK7086-4CF71-1CG2 |
|---|---|
| Motor type | Permanent-magnet synchronous motor; High Dynamic |
| Rated power | PN=2kW |
| DC voltage | UDC=600V |
| Rated speed | 3,000 rpm (100 K) |
| Rated torque | 6.5 Nm (100 K) |
| Encoder | Encoder AM24DQI: 24 bits absolute + 12 bits multi-turn; DRIVE-CLiQ interface |
| Mounting | IM B5 (IM V1, IM V3) |
| Cooling | Natural cooling |
| Protection | IP65 and DE flange IP67 |
| Holding brake | without holding brake |
Frequently Asked Questions
What motor type is 1FK7086-4CF71-1CG2?
It has a permanent-magnet synchronous motor design and is identified as High Dynamic.
What encoder and interface does this motor have?
It has an Encoder AM24DQI with 24 bits absolute and 12 bits multi-turn, plus a DRIVE-CLiQ interface.
What mounting and connector configuration does it use?
It uses IM B5 (IM V1, IM V3) mounting, a plain shaft with tolerance N, and rotatable signals and power connectors. The connector size is M40.
Does the motor include a holding brake?
It is without holding brake.
What information should I provide for a quotation?
Provide the required quantity, destination, requested date, and any project list or verification details.