Key Features
- Rated performance: PN=2.4 kW, rated speed 4,500 rpm (100 K), rated torque 5.0 Nm (100 K), and efficiency 93.0 %.
- Absolute Encoder feedback: Encoder AM20DQI provides 20 bits with resolution 1048576 and 12 bits multiturn with a traversing range of 4096 revolutions; it has a DRIVE-CLiQ interface.
- Mounting and shaft: Design acc. to Code I: IM B5 (IM V1, IM V3), with a rotatable flange 1 power connector and shaft with fitted Feather key, tolerance N.
- Cooling and protection: Natural cooling; degree of protection IP65 and DE flange IP67.
- Holding brake: Permanent-magnet holding brake with holding torque 13.0 Nm and DC 24 V ± 10 % power supply voltage.
- Connectors and monitoring: M23 electrical connectors for rotatable signals and power connections, plus a Pt1000 temperature sensor.
Technical Summary
| Product type | Permanent-magnet synchronous motor; High Dynamic |
|---|---|
| Rated power | PN=2.4 kW |
| Rated speed | 4,500 rpm (100 K) |
| Rated torque | 5.0 Nm (100 K) |
| Encoder | AM20DQI absolute Encoder, 20 bits + 12 bits multiturn, DRIVE-CLiQ interface |
| Mounting | IM B5 (IM V1, IM V3), flange 1 |
| Cooling | Natural cooling |
| Protection | IP65 and DE flange IP67 |
| Connector | M23; signals and power connectors rotatable |
| Holding brake | Permanent-magnet brake; holding torque 13.0 Nm |
| Power supply voltage | DC 24 V ± 10 % |
Frequently Asked Questions
What Encoder is fitted to Siemens 1FK7064-4CH71-1RB2?
It has an AM20DQI absolute Encoder with 20 bits, resolution 1048576, 12 bits multiturn, a traversing range of 4096 revolutions, and a DRIVE-CLiQ interface.
What mounting and connector configuration does this motor have?
It has design IM B5 (IM V1, IM V3), a flange 1 power connector, and M23 connectors for signals and power that are rotatable.
What protection and cooling does the motor provide?
It has Natural cooling, degree of protection IP65, and DE flange IP67.
What configuration should I provide for a quotation?