Product information
Overview
Key Features
- Performance: Optimum power: 1.2 kW; optimum speed: 3,000 rpm; rated torque (100 K): 3.7 Nm.
- Feedback interface: Absolute encoder AM20DQI with 20 bits, 1048576 resolution, 512 S/R encoder-internal, and 12 bits multi-turn over 4096 revolutions; DRIVE-CLiQ interface.
- Holding brake: Permanent-magnet brake with 4.0 Nm holding torque and DC 24 V ± 10 % power supply.
- Mounting and connections: Design: IM B5 (IM V1, IM V3); M23 connector size; signals and power connectors are rotatable; shaft end has a feather key.
- Cooling and protection: Natural cooling and IP65 degree of protection.
- Motor configuration: Permanent-magnet synchronous motor, High Dynamic, with Pt1000 temperature sensor and 6 poles.
Technical Summary
| Product type | Permanent-magnet synchronous motor |
|---|---|
| Optimum power | 1.2 kW |
| Optimum speed | 3,000 rpm |
| Rated speed (100 K) | 3,000 rpm |
| Rated torque (100 K) | 3.7 Nm |
| Maximum torque | 13.0 Nm |
| Rated current | 3.5 A |
| Encoder system | Absolute encoder AM20DQI: 20 bits + 12 bits multi-turn |
| Encoder interface | DRIVE-CLiQ |
| Mounting | IM B5 (IM V1, IM V3) |
| Holding brake | Permanent-magnet brake, 4.0 Nm holding torque |
| Degree of protection | IP65 |
Frequently Asked Questions
What is the exact motor configuration?
It is the Siemens SIMOTICS S 1FK7044-4CF71-1RB1 permanent-magnet synchronous motor, High Dynamic, with 1.2 kW optimum power and 3,000 rpm optimum speed.
Which encoder and interface does it have?
It has an absolute encoder AM20DQI with 20 bits, 1048576 resolution, 512 S/R encoder-internal, 12 bits multi-turn over 4096 revolutions, and a DRIVE-CLiQ interface.
What mounting and connectors are supplied?
The design is IM B5 (IM V1, IM V3). The motor has M23 connectors for signals and power, and the connectors are rotatable.
Does it include a holding brake?
It has a permanent-magnet holding brake with 4.0 Nm holding torque and DC 24 V ± 10 % power supply.
What details should I provide for a quotation?
Provide the required quantity, destination, requested date, and project or MRO list for verification.