Product information
Overview
Key Features
- Rated power: Rated power is 7.50 kW | 10.00 hp for low overload and 5.50 kW | 7.50 hp for high overload.
- Input and output: Input and output each have 3 AC phases. Input voltage is 380 … 480 V +10 % -20 % at 47 … 63 Hz.
- Overload capability: Low overload: 150% for 3s, 110% for 57s and 100% for 240s. High overload: 200% for 3s, 150% for 57s and 100% for 240s.
- Communication and I/O: Communication: PROFINET, EtherNet/IP. The interface has 6 digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential input and 1 non-isolated analog output.
- Control and protection: It supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law and sensorless vector control. Protection: IP20 / UL open type.
- Connections and dimensions: Line-side, motor-end and DC-link connections use plug-in screw terminals. Dimensions are 100 mm (3.94 in) wide and 203 mm (8.19 in) deep; frame size: FSB.
Technical Summary
| Product lifecycle | Active Product |
|---|---|
| Input voltage | 380 … 480 V +10 % -20 % |
| Input frequency | 47 … 63 Hz |
| Rated power, low overload | 7.50 kW | 10.00 hp |
| Rated power, high overload | 5.50 kW | 7.50 hp |
| Communication | PROFINET, EtherNet/IP |
| Digital inputs | 6 standard; 1 fail-safe |
| Control techniques | V/f linear / square-law / parameterizable; V/f with flux current control (FCC); V/f ECO linear / square-law; sensorless vector control |
| Protection | IP20 / UL open type |
| Frame size | FSB |
Frequently Asked Questions
What is the exact Siemens model and converter type?
The exact model is 6SL3210-1KE21-7UF1, a SINAMICS G120C compact converter.
What input supply does this converter use?
Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz.
Which communication interfaces and I/O are provided?
Communication: PROFINET and EtherNet/IP. I/O includes 6 digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential input and 1 non-isolated analog output.
What protection and mechanical configuration does it have?
Protection is IP20 / UL open type. Frame size is FSB, with dimensions of 100 mm wide and 203 mm deep.
What information should I provide for a quotation?
Provide the required quantity, destination and requested date so the requirement can be reviewed.