- Electrical ratings: Input and output: 3 AC. Line voltage: 380 … 480 V +10 % -20 %; line frequency: 47 … 63 Hz.
- Rated output power: Rated power is 3.00 kW | 4.00 hp for low overload and 2.20 kW | 3.00 hp for high overload.
- Control and frequency: Output frequency is 0 … 240 Hz for vector control and 0 … 550 Hz for V/f control. Sensorless vector control is available.
- I/O interface: The interface has 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog input, and 1 non-isolated analog output.
- Communication and safety: Fieldbus communication: USS/MODBUS RTU. Safe Torque Off is integrated.
- Connections and protection: The unit has plug-in screw terminals, IP20 / UL open type protection, FSA frame size, and air cooling using an integrated fan.
Technical Summary
| Product_lifecycle | Active Product |
|---|---|
| Input line voltage | 380 … 480 V +10 % -20 % |
| Input line frequency | 47 … 63 Hz |
| Rated output power (LO) | 3.00 kW | 4.00 hp |
| Rated output power (HO) | 2.20 kW | 3.00 hp |
| Output frequency for vector control | 0 … 240 Hz |
| Output frequency for V/f control | 0 … 550 Hz |
| I/O interface | 6DI, 2DO, 1AI, 1AO, 1 fail-safe digital input |
| Communication | USS/MODBUS RTU |
| Protection | IP20 / UL open type |
| Frame size | FSA |
Frequently Asked Questions
What is the input voltage and frequency of 6SL3210-1KE17-5UB1?
Input line voltage is 380 … 480 V +10 % -20 %, and input line frequency is 47 … 63 Hz.
Which control and communication functions does this converter have?
It has sensorless vector control, V/f control up to 0 … 550 Hz, and USS/MODBUS RTU communication. Integrated Safe Torque Off is included.
What are the protection and mechanical details?
Protection is IP20 / UL open type. The frame size is FSA, with width 73 mm (2.87 in) and depth 203 mm (7.99 in).