Product information
Overview
Key Features
- High-overload output: Rated power: 22.00 kW | 30.00 hp (HO); 200% for 3 s, 150% for 57 s and 100% for 240 s at 0 … 50 °C ambient temperature.
- Light-overload output: Rated power: 30.00 kW | 40.00 hp (LO); 150% for 3 s, 110% for 57 s and 100% for 240 s at 0 … 40 °C ambient temperature.
- Three-phase supply: Input: 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz.
- Output and control ranges: Output frequency: 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control; maximum output current: 90.00 A.
- Connections and motor cable length: Line-side and motor-end connections use M6 bolts with 10.00 … 35.00 mm2 conductors. Maximum motor cable length: 50 m shielded or 100 m unshielded.
- Configuration and protection: Frame size FSD, dimensions 275 × 512 × 204 mm (W × H × D), IP20 / UL open type, integrated Class A filter, without control unit and BOP.
Technical Summary
| Product type | SINAMICS G120 PM250 power module |
|---|---|
| Product lifecycle | Active Product |
| Input supply | 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz |
| Rated power (HO) | 22.00 kW | 30.00 hp |
| Rated power (LO) | 30.00 kW | 40.00 hp |
| Rated current (HO) | 45.00 A output; 42.00 A input |
| Rated current (LO) | 60.00 A output; 56.00 A input |
| Maximum output current | 90.00 A |
| Output frequency | 0 … 200 Hz vector control; 0 … 550 Hz V/f control |
| Connections | M6 bolt; 10.00 … 35.00 mm2 (AWG 8 … AWG 2) |
| Protection and configuration | IP20 / UL open type; without control unit and BOP |
Frequently Asked Questions
What is the exact product type and order number?
It is the Siemens SINAMICS G120 PM250 power module, order number 6SL3225-0BE32-2AA0.
What are the high-overload and light-overload ratings?
High overload is 22.00 kW | 30.00 hp, with 200% for 3 s, 150% for 57 s and 100% for 240 s at 0 … 50 °C. Light overload is 30.00 kW | 40.00 hp, with 150% for 3 s, 110% for 57 s and 100% for 240 s at 0 … 40 °C.
What control frequency ranges are supported?
The output frequency is 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control.
What is included in this configuration?
It is without a control unit and BOP. It has an integrated Class A filter and the possibility of regeneration.
What quantity, destination and requested date should be included for a quotation?
Please provide the required quantity, destination and requested date so the configuration can be reviewed for quotation.