Product information
Overview
Key Features
- Rated performance: PN=2 kW, rated speed 3,000 rpm (100 K), rated torque 6.5 Nm (100 K), and efficiency 93.0 %.
- Absolute encoder feedback: Encoder AM20DQI: absolute encoder 20 bits (resolution 1048576, encoder-internal 512 S/R) + 12 bits multi-turn (traversing range 4096 revolutions), with DRIVE-CLiQ interface.
- Mechanical configuration: Permanent-magnet synchronous motor, High Dynamic, with IM B5 (IM V1, IM V3) design and a Feather key shaft end.
- Connections and cooling: Rotatable connectors for signals and power, M40 connector size, and Natural cooling.
- Protection and braking: Degree of protection IP64 and without holding brake.
- Lifecycle and weight: Active Product with a net motor weight of 23.0 kg.
Technical Summary
| Product | Siemens 1FK7086-4CF71-1RA0 SIMOTICS S |
|---|---|
| Motor type | Permanent-magnet synchronous motor; High Dynamic |
| Rated power | PN=2 kW |
| Rated speed | 3,000 rpm (100 K) |
| Rated torque | 6.5 Nm (100 K) |
| Encoder | Encoder AM20DQI: absolute encoder 20 bits + 12 bits multi-turn, DRIVE-CLiQ interface |
| Mounting | IM B5 (IM V1, IM V3) |
| Cooling | Natural cooling |
| Connector | M40; connectors for signals and power rotatable |
| Protection | IP64 |
| Holding brake | without holding brake |
Frequently Asked Questions
What is the rated performance of Siemens 1FK7086-4CF71-1RA0?
It has PN=2 kW, rated speed 3,000 rpm (100 K), rated torque 6.5 Nm (100 K), and rated current 5.7 A.
Which encoder and interface does this motor have?
It has an Encoder AM20DQI with an absolute encoder 20 bits (resolution 1048576, encoder-internal 512 S/R) + 12 bits multi-turn (traversing range 4096 revolutions), with DRIVE-CLiQ interface.
What are the mounting and connector details?
The design is IM B5 (IM V1, IM V3). The connector size is M40, and the connectors for signals and power are rotatable.
Does this configuration include a holding brake?
It is without holding brake.
What should be included in a quotation request?
Please provide the required quantity, destination, requested date, and any project list or verification requirements.