Product information
Overview
Applications
- Electrical parameter measurement: Measures voltage, current, active power, reactive power and frequency in stationary panels in closed rooms.
Key Features
- Electrical measurement: Measures voltage, current, active power, reactive power and frequency in 3-phase systems.
- Measured values and accuracy: Supports RMS voltage measurement and TRMS current measurement; active energy accuracy is Cl. 0.5 acc. to IEC62053-22, while reactive energy is Class 2 according to IEC61557-12 and/or IEC62053-23.
- Voltage and current inputs: Rated measurable voltage is 690 V between line conductors and 400 V between (PE)N and L; rated current values are 1 A and 5 A. External voltage and current transformers can extend the measuring ranges.
- Communication: Has 1 Fast Ethernet interface with a 10 000 kbit/s transfer rate and MODBUS TCP support. Modbus RTU, PROFINET and PROFIBUS are optional.
- Display and supply: Has a white LCD display measuring 54 mm high and 72 mm wide, with 4 keys. Supply: wide-range AC/DC, 95 … 240 V AC or 110 … 340 V DC.
- Installation and protection: Size 96 device with 96 mm height, 96 mm width, 56 mm depth and 51 mm installation depth. Vertical mounting, IP65 front protection and ring cable lug connection.
Technical Summary
| Product family | SENTRON 7KM PAC3200 |
|---|---|
| Measurement functions | Voltage, current, active power, reactive power and frequency |
| System configuration | 3-phase |
| Rated measurable voltage | 690 V L-L; 400 V L-N |
| Rated current | 1 A and 5 A |
| Communication | 1 Fast Ethernet interface; MODBUS TCP |
| Optional interfaces | Modbus RTU / PROFINET / PROFIBUS |
| Display | LCD, 54 mm x 72 mm, white background |
| Supply | 95 … 240 V AC; 110 … 340 V DC |
| Connection | Ring cable lug connection |
| Mounting and protection | Vertical mounting; IP65 front protection |
Frequently Asked Questions
What measurements does the 7KM2112-0BA00-2AA0 support?
It measures voltage, current, active power, reactive power and frequency.
What voltage and current values does this measuring device support?
The rated measurable voltage is 690 V between line conductors and 400 V between (PE)N and L. Rated current values are 1 A and 5 A.
Which communication interface is included?
It has 1 Fast Ethernet interface with MODBUS TCP support. Modbus RTU, PROFINET and PROFIBUS are optional.
How is the device mounted and connected?
It uses vertical mounting and a ring cable lug connection. The front protection class is IP65.
What quantity and destination should I include in a quotation request?
Please include the required quantity and destination, along with any project list or requested date.