- Power and torque: PN=2.4 kW; M0=12 Nm (100 K); rated torque is 5.0 Nm (100 K).
- Speed performance: NN=4500 rpm; maximum permissible mechanical and inverter speed is 7,500 rpm; optimum speed is 3,500 rpm.
- Absolute Encoder feedback: Absolute Encoder AM20DQI with 20 bits, resolution 1048576, encoder-internal 512 S/R and 12 bits multi-turn over 4096 revolutions, with DRIVE-CLiQ interface.
- Mounting and shaft: IM B5 design (IM V1, IM V3); M23 connector size; shaft with fitted Feather key and tolerance N; connectors for signals and power are rotatable.
- Cooling and protection: Natural cooling; degree of protection IP65, with the DE flange at IP67; supplied without holding brake.
Technical Summary
| Product type | Permanent-magnet synchronous motor; High Dynamic |
|---|---|
| Rated power | PN=2.4 kW |
| DC link voltage | UDC=600 V |
| Rated speed (100 K) | 4,500 rpm |
| Rated torque (100 K) | 5.0 Nm |
| Static torque (100 K) | 12.00 Nm |
| Rated current | 7.0 A |
| Encoder system | Absolute Encoder AM20DQI: 20 bits + 12 bits multi-turn; DRIVE-CLiQ interface |
| Mounting design | IM B5 (IM V1, IM V3) |
| Cooling | Natural cooling |
| Degree of protection | IP65 and DE flange IP67 |
| Holding brake | without holding brake |
Frequently Asked Questions
What is the exact motor configuration?
It is the Siemens 1FK7064-4CH71-1RA2 SIMOTICS S permanent-magnet synchronous motor with PN=2.4 kW, UDC=600 V, natural cooling and IM B5 design (IM V1, IM V3).
Which Encoder and feedback interface does it have?
It has an absolute Encoder AM20DQI with 20 bits, 12 bits multi-turn over 4096 revolutions and a DRIVE-CLiQ interface.
Which connector and protection details should be verified?
The connector size is M23, and the signal and power connectors are rotatable. The degree of protection is IP65, with the DE flange at IP67.
Does this configuration include a holding brake?
It is without holding brake.
What details should I provide for a quotation?