Product information
Overview
Key Features
- Rated motor performance: 109 kW, 2602 Nm, 260 A and 295 V at 400 r/min; 136 kW, 2598 Nm, 260 A and 365 V at 500 r/min; 164 kW, 2610 Nm, 260 A and 440 V at 600 r/min.
- Cooling and protection: Water cooling with IP55 degree of protection.
- Incremental encoder: SIN/COS 1 VPP encoder with 2048 S/R and C and D track; encoder IC2048S/R.
- Temperature sensor: KTY 84-130 temperature sensor.
- Mechanical configuration: DESIGN IM B3 (IMV6), shaft with fitted key, half-key balancing, standard bearing and vibration severity grade A; shaft accuracy A, flange accuracy GR.N.
- Connections and lifecycle: Terminal box above, cable entry on the right, signal connection at the D-end. Product cancellation.
Technical Summary
| Product type | SIMOTICS M compact asynchronous motor |
|---|---|
| Order number | 1PH8288-1MB20-2AA1 |
| Performance at 400 r/min | 109 kW, 2602 Nm, 260 A, 295 V |
| Performance at 500 r/min | 136 kW, 2598 Nm, 260 A, 365 V |
| Performance at 600 r/min | 164 kW, 2610 Nm, 260 A, 440 V |
| Cooling | Water cooling |
| Degree of protection | IP55 |
| Encoder | Incremental SIN/COS 1 VPP, 2048 S/R, with C and D track |
| Temperature sensor | KTY 84-130 |
| Mechanical design | IM B3 (IMV6), shaft with fitted key, half-key balancing |
| Connections | Terminal box above; cable entry on the right; signal connection at the D-end |
Frequently Asked Questions
What motor performance values apply to 1PH8288-1MB20-2AA1?
At 400 r/min it has 109 kW, 2602 Nm, 260 A and 295 V; at 500 r/min, 136 kW, 2598 Nm, 260 A and 365 V; at 600 r/min, 164 kW, 2610 Nm, 260 A and 440 V.
Which encoder is fitted to this motor?
It has an incremental SIN/COS 1 VPP encoder with 2048 S/R and C and D track, encoder IC2048S/R.
How is the motor configured mechanically and connected?
It has DESIGN IM B3 (IMV6), a shaft with fitted key, half-key balancing, a terminal box above, cable entry on the right and signal connection at the D-end.
What quantity, destination and requested date should be included for a quotation?
Include the required quantity, destination and requested date so the MRO or project quotation can be prepared.